Performs comprehensive monitoring of four critical systems in one compact organic LED digital monitor
One input monitors the DC voltage, state-of-charge, current for one battery bank and another input monitors the voltage of an additional battery bank. Alarms include high and low voltage, high current, and low battery.
The VSM monitors a single AC voltage, current, and frequency. Alarms include high and low voltage, high current, and high and low frequency.
The VSM has two inputs that can be configured as a bilge or tank monitor. When configured as a bilge input, monitoring functions include pump active, cycle count in the last 24-hours, average cycles in a typical 24-hour period, and total cycles. High alarms can be set for both the minutes of run time in the last hour as well as the number or cycle counts in the last 24-hours. When configured as a tank input, tank status can be represented in both capacity (gallons or liters) or as a percentage of capacity. Custom tank shapes can be auto-calibrated or programmed. Both high and low level alarms can be set for all tanks.
NMEA 2000 certified and uses standard connectors. This allows a single network backbone to be installed for multiple NMEA 2000 devices. The M2 VSM can share certain monitoring functions with other NMEA 2000 compliant screens, such as CZone Displays Touch 5 & Touch 10.
Specifications
Display Size 55mm x 28mm
Power Supply 7V–70V DC
Power Consumption 0.5W–1.0W*
NMEA 2000 Load Equivalency 1
DC Voltage
Nominal 12V, 24V, 36V, 48V
Range 0V–70V DC
Resolution 0.01V DC
Accuracy +/- 1%
DC Current
Shunt Included 1 × PN 8255 (500A / 50mV)
Range −500A to 500A
Accuracy +/- 2%
Resolution (100 to 500) 1A
Resolution (0.0 to 99.9) 0.1A
Alarm Activation High and Low Voltage, High Current and Low Battery
AC Voltage
Range 40V–300V AC (RMS)
Accuracy +/- 1%
Resolution 1V AC
AC Current
Range 0A to 150A (300A optional)**
Accuracy +/- 2%
Resolution (100 to 150) 1A
Resolution (0.0 to 99.9) 0.1A
Current Transformer 1 × PN 8256 (150A / 50mA)
Alarm Activation High and Low Voltage, Current, & Frequency
Frequency
Range 40Hz–90Hz
Resolution 1Hz
Power
Range 0W–45kW
Resolution (0W–9990W) 10W
Resolution (10kW–45kW) 0.1kW
Tanks***
Tank Level Alarm High/Low Levels
Senders North American 240Ω–33Ω
European 10Ω–180Ω
Blue Sea Systems Ultrasonic 5V Sender Custom
Sender Resolution 1%
Custom Tank Shapes Auto Calibration
Bilge Alarm Notification Run time per hour Cycles per 24-hour
Regulatory
Monitor face is IP66 – protected against powerful water jets when installed
according to instructions
* Variable with voltage, display intensity, and sleep mode
** Will achieve 300A with an optional current transformer PN 1829
*** Compatible with bilge monitors with external float switches or with automatic
bilge switches that indicate on status via a 12V output.